Cleveland
COOK CHILL SYSTEMS
Cook/Chill Systems
MODELS:
ꢀ
ꢀ
GFB-6
GFB-10
ꢀ
ꢀ
GFB-15
GFB-20
ꢀ
ꢀ
GFB-30
GFB-50
ꢀ
GFB-60
GAS FIRED STEAM BOILERS
Cleveland Standard Features
I Complete skid-mounted and piped, gas fired Steam Boiler with
Vertical Return System and Blow Down Separator
I Available for Pressure Ratings from 15 to 150 psi (specify
required operating pressure)
I Vertical Tubeless design
I Fully insulated Boiler with top mounted, down-fired burners
I High Temperature Insulation assists thermal efficiency of 80%
I Spinning Cyclonic Flame travels down the entire length of the
Combustion Chamber
I Top Flame Retainer increases occupancy time of flue gases to
complete combustion process
I Operating Pressure Control and High Limit Pressure Control
with Manual Reset
I Water Column with Water Gauge Assembly
I All necessary valves are included
I Automatic Water Feed System with probe type Water Level
Controls and single phase Motor for Pump
I Steam Outlet conveniently located at top of Boiler
I Control Panel factory mounted and wired, ready for power con-
nection
I Built and stamped to A.S.M.E. Code
I Registered with the National Board of Boiler & Pressure Vessel
Inspectors
Short Form Specifications
I Accepted for use in U.S.D.A. Inspected Facilities
Shall be CLEVELAND Model GFB -____, gas-fired, vertical, tube-
less LARGE STEAM BOILER System, _____H.P. (horse power);
Complete with Power Burners; Skid mounted and piped with
Vertical Condensate Return System and Blow-Down Separator
Package; Factory assembled as a self-contained unit, in accor-
dance to U.L. requirements, and A.S.M.E. Section 1 (one) Code;
Guaranteed production of _______ pounds of Steam per hour at
212˚F.
Options & Accessories
Ë Stainless Steel outer Jacket
Ë Automatic Boiler Blow-down Controls
Ë Applicable Controls to meet the various special insurance,
local, state or federal code requirements
Ë Electric heated Steam Boilers
Ë Oil-fired Steam Boilers
Ë Cooling Kit for boiler drain
Ë Aquastat automatic drain cooling kit
Ë Larger models availabe on request
SECT. XIV PAGE 53
0907
1333 East 179 St.,
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Email: Steam@ClevelandRange.com
Cleveland, Ohio, U.S.A. 44110
|
Audiovox BA200 User Manual
Audiovox MMD10 User Manual
Cateye CC VL500 User Manual
Citizen Calculator SRP 145N User Manual
Crown Boiler KSZ075 User Manual
Gitzo G1158T User Manual
Haier HB500BSS User Manual
JBL GTO24001 User Manual
JVC Car Stereo System KD R326 User Manual
JVC FSUN3117 312 KD S777R User Manual